Salient features of Combined NE.Khawdungsei, Chiahpui & Khawkawn Water Supply Scheme | ||||||||
Division : Khawzawl WATSAN Division | ||||||||
Sub Division : Ngopa WATSAN Sub Division | ||||||||
Name of Scheme : Combined N.E.Khawdungsei, Chiahpui & Khawkawn WSS (Solar Pumping) | ||||||||
Year of Commissioning : 2020 | ||||||||
Design population : 6011 | ||||||||
Design lpcd : 55 | ||||||||
Sl. No | Name of Equipment | Specification | Present Condition | |||||
Stage-I | Stage-II | |||||||
1 | Common Feeder Solar Submersible pumpset (Centrifugal) | Model | = | PSK2-40C-SJ42-19 | PSK2-40C-SJ42-19 | Running Codition | ||
Max head | = | 200m | 200m | |||||
Max flow | = | 63m³/hr | 63m³/hr | |||||
Cap.of Power plant | = | 40.950Kwp (SPV) | 40.950Kwp (SPV) | |||||
Rated Power | = | 30 Kw | 30 Kw | |||||
Rated speed | = | 1400-2905 rpm | 1400-2905 rpm | |||||
Input Voltage | = | 380 V | 380 V | |||||
Insulation | = | F Class | F Class | |||||
Enclosure | = | IP 68 | IP 68 | |||||
Motor Efficiency | = | 84% | 84% | |||||
Pumpset efficiency | = | 78% | 78% | |||||
Length of pumpset | = | 3.54 m | 3.54 m | |||||
Weight | = | 164Kgs | 164Kgs | |||||
Submersion | = | 150m | 150m | |||||
2 | N.E.Khawdungsei Solar Submersible pumpset (Centrifugal) | Model | = | PSK2-21C-SJ17-26 | PSK2-21C-SJ17-26 | Running Codition | ||
Max head | = | 220m | 220m | |||||
Max flow | = | 22m³/hr | 22m³/hr | |||||
Cap.of Power plant | = | 22.10Kwp (SPV) | 22.10Kwp (SPV) | |||||
Rated Power | = | 15 Kw | 15 Kw | |||||
Rated speed | = | 1400-2905 rpm | 1400-2905 rpm | |||||
Input Voltage | = | 380 V | 380 V | |||||
Insulation | = | F Class | F Class | |||||
Enclosure | = | IP 68 | IP 68 | |||||
Motor Efficiency | = | 84% | 84% | |||||
Pumpset efficiency | = | 72% | 72% | |||||
Length of pumpset | = | 2.633 m | 2.633 m | |||||
Weight | = | 118Kgs | 118Kgs | |||||
Submersion | = | 150m | 150m | |||||
3 | Khawkawn Solar Submersible pumpset (Centrifugal) | Model | = | PSK2-9C-SJ8-44 | PSK2-9C-SJ8-44 | Running Codition | ||
Max head | = | 180m | 180m | |||||
Max flow | = | 12m³/hr | 12m³/hr | |||||
Cap.of Power plant | = | 10.40Kwp (SPV) | 10.40Kwp (SPV) | |||||
Rated Power | = | 7.5 Kw | 7.5 Kw | |||||
Rated speed | = | 1400-2905 rpm | 1400-2905 rpm | |||||
Input Voltage | = | 380 V | 380 V | |||||
Insulation | = | F Class | F Class | |||||
Enclosure | = | IP 68 | IP 68 | |||||
Motor Efficiency | = | 80% | 80% | |||||
Pumpset efficiency | = | 68% | 68% | |||||
Length of pumpset | = | 2.73 m | 2.73 m | |||||
Weight | = | 78Kgs | 78Kgs | |||||
Submersion | = | 150m | 150m | |||||
4 | Chiahpui Solar Submersible pumpset (Centrifugal) | Model | = | PS2-4000C-SJ5-25 | PS2-4000C-SJ5-25 | Running Codition | ||
Max head | = | 140m | 140m | |||||
Max flow | = | 7m³/hr | 7m³/hr | |||||
Cap.of Power plant | = | 4.55Kwp (SPV) | 4.55Kwp (SPV) | |||||
Rated Power | = | 4.00Kw | 4.00 Kw | |||||
Rated speed | = | 900-3300 rpm | 900-3300 rpm | |||||
Input Voltage | = | 240 V | 240 V | |||||
Insulation | = | F Class | F Class | |||||
Enclosure | = | IP 68 | IP 68 | |||||
Motor Efficiency | = | 92% | 92% | |||||
Pumpset efficiency | = | 54% | 54% | |||||
Length of pumpset | = | 0.94 m | 0.94 m | |||||
Weight | = | 18Kgs | 18Kgs | |||||
Submersion | = | 150m | 150m |